| Operating Temperature | |||||
| Product | Continuous (°C) |
Short Term |
|||
|---|---|---|---|---|---|
| Type | Version | ||||
| Unsealed metal-shell connector (All Series) |
Contact block material | PEEK | -65 to +200 | -65 to +220 | |
| Teflon® | -65 to +150 | -65 to +175 | |||
| PBT | -65 to +135 | -65 to +150 | |||
| Sealed metal-shell connector (All Series) |
Cable mounted | -65 to +135 | -65 to +175 | ||
| Panel mounted | -25 to +135 | -25 to +150 | |||
| Unsealed plastic-shell connector |
Series 4032 and Series 405 | Contact block material | PEEK | ||
| -30 to +180 | -30 to +200 | ||||
| Teflon® | -30 to +150 | -30 to +175 | |||
| PBT | -30 to +135 | -30 to +150 | |||
| Protective boot | All | -60 to +100 | -60 to +125 | ||
| Cable strain relief | Standard version | -60 to +100 | -60 to +125 | ||
| Autoclaveable version | -60 to +180 | -60 to +200 | |||
| Sealing cap | Plastic version¹ | -40 to +105 | -40 to +105 | ||
| Metal version | -20 to +200 | -20 to +250 | |||
| Panel spacer | All | -60 to +250 | |||
| Color coding washer | All | -20 to +60 | |||
| Insulating washer | Series 101 and 102 | -30 to +60 | -20 to +70 | ||
| Series 103 and 104 | -40 to +105 | -40 to +150 | |||
| ¹ For plastic version equipped with a Viton® O-ring: | -20 to +200 | -20 to +250 |